Search results for " shrinkage"
showing 10 items of 23 documents
Automatic Processing Scheme for Low Laser Invasiveness Electro Optical Frequency Mapping mode
2016
International audience; Electro optical techniques are efficient backside contactless techniques usually used for design debug and defect location in modern VLSI. Unfortunately, the signal to noise ratio is quite low and depends on laser power with potential device stress due to long acquisition time or high laser power, especially in up to date technologies. Under these conditions, to maintain a good signal or image quality, specific signal or image processing techniques can be implemented. In this paper, we proposed a new spatial filtering by stationary wavelets and contrast enhancement which allows the use of low laser power and short acquisition time in image mode.
Epoxy resins as a matrix material in advanced fiber-reinforced polymer (FRP) composites
2013
Abstract: This chapter discusses the epoxy resins which, thanks to their good and versatile properties, can be considered nowadays the most important class of thermosetting polymers. In particular the chapter first reviews both the epoxy resins commonly available on the market, including a new class of bio-derived epoxy resins, and the most-used curing agents. it then describes the principal characteristics of the epoxy resins and how it is possible to enhance them by adding several fillers to the epoxy system. Finally, the chapter analyzes the main engineering fields in which epoxy resins find application today and their possible future utilization.
Water retention behaviour of compacted and reconstituted scaly clays
2020
The paper presents the results of an experimental research devoted to investigate the response to suction variations of a scaly clay in compacted and reconstituted conditions. Different experimental techniques (axis translation, vapour equilibrium, dew point psychrometer suction measurements) were combined in order to explore the water retention properties in a wide suction range (0 ÷ 110 MPa). Experimental results allowed to define the water retention domains for a constant reference void ratio, highlighting the significant role of the microstructure on the response of the investigated clays. In particular, the collected results showed that in the low-medium suction range, the peculiar mic…
The Role of Tumor Volume in ‘Reoxygenation’ upon Cyclophosphamide Treatment
1995
The effect of cyclophosphamide (CP) injection (60 mg/kg i.p., single dose) on volume growth and tissue oxygenation (pO2 distribution) was investigated in rat DS-sarcomas. CP was administered 4 days after subcutaneous (s.c.) tumor implantation (volume approximately 0.35 ml). Polarographic pO2 measurements were performed in the subcutis at the hind foot dorsum and in tumors 72 h after CP administration. The oxygenation status of these tissues was compared with that of saline-treated controls. CP-injection caused a mean growth delay of 11 days in DS-sarcomas and had no impact on the oxygenation status of the subcutis. In contrast, in s.c. growing DS-sarcomas the pO2 distribution improved signi…
Synthesis and biological evaluation of new imidazo[2,1-b][1,3,4]thiadiazole derivatives: as anticancer and antibiofilm agents, and preclinical invest…
2020
Relation of early tumor shrinkage (ETS) observed in first‐line treatment to efficacy parameters of subsequent treatment in FIRE‐3 (AIOKRK0306)
2016
We explored the association of early tumor shrinkage (ETS) and non-ETS with efficacy of first-line and consecutive second-line treatment in patients with KRAS wild-type metastatic colorectal cancer treated in FIRE-3. Assessment of tumor shrinkage was based on the sum of longest diameters of target lesions, evaluated after 6 weeks of treatment. Shrinkage was classified as ETS (shrinkage by ≥ 20%), mETS (shrinkage by 0 to20%), mPD (minor progression0 to20%) and PD (progression ≥20%). Overall survival (OS) was 33.2 (95% CI 28.0-38.4) months in ETS patients, while non-ETS was associated with less favorable outcome (mETS 24.0 (95% CI 21.2-26.9) months, mPD 19.0 (95% CI 13.0-25.0) months, PD 12.8…
Evaluation of marginal sealing quality of restorations with low shrinkage composite resins
2020
Background This study compared the quality of marginal sealing in the gingival wall of class II preparations of two low-shirinkage resins of the bulk fill type with a conventional resin isolated or associated with a glass ionomer cement (GIC). Material and methods 40 human molars were divided into 4 groups and 80 occlusal-mesial and occlusal-distal restorations were performed with the following materials: SureFil SDR flow, Filtek Bulk Fill Posterior, Z250 resins and Riva Light Cure GIC. 40 restorations were evaluated in Scanning Electron Microscopy (SEM) with Elemental Microanalysis Spectrometry (EDS) initially and the remainder after a period of 6 months of aging in a 37 ± 5°C oven. An ave…
Propagation pattern analysis during atrial fibrillation based on sparse modeling.
2012
In this study, sparse modeling is introduced for the estimation of propagation patterns in intracardiac atrial fibrillation (AF) signals. The estimation is based on the partial directed coherence function, derived from fitting a multivariate autoregressive model to the observed signal using least-squares (LS) estimation. The propagation pattern analysis incorporates prior information on sparse coupling as well as the distance between the recording sites. Two optimization methods are employed for estimation of the model parameters, namely, the adaptive group least absolute selection and shrinkage operator (aLASSO), and a novel method named the distance-adaptive group LASSO (dLASSO). Using si…
Muscle activity patterns and spinal shrinkage in office workers using a sit–stand workstation versus a sit workstation
2016
Reducing sitting time by means of sit-stand workstations is an emerging trend, but further evidence is needed regarding their health benefits. This cross-sectional study compared work time muscle activity patterns and spinal shrinkage between office workers (aged 24-62, 58.3% female) who used either a sit-stand workstation (Sit-Stand group, n = 10) or a traditional sit workstation (Sit group, n = 14) for at least the past three months. During one typical workday, muscle inactivity and activity from quadriceps and hamstrings were monitored using electromyography shorts, and spinal shrinkage was measured using stadiometry before and after the workday. Compared with the Sit group, the Sit-Stan…
A new tuning parameter selector in lasso regression
2019
Penalized regression models are popularly used in high-dimensional data analysis to carry out variable selction and model fitting simultaneously. Whereas success has been widely reported in literature, their performance largely depend on the tuning parameter that balances the trade-off between model fitting and sparsity. In this work we introduce a new tuning parameter selction criterion based on the maximization of the signal-to-noise ratio. To prove its effectiveness we applied it to a real data on prostate cancer disease.